LB
|
address |
instruction |
Notes |
read and write properties |
|
60000-60099 |
Initial setting ON |
These bits can be initialized to ON at system startup |
R/W |
|
60100 |
Recipe download |
Triggering this bit can write the data in the current RWI to the device, and reset it after completion |
R/W |
|
60101 |
recipe upload |
Triggering this bit can read the recipe from the device to the RWI register area, reset after completion |
R/W |
|
60102 |
Recipe save |
Triggering this bit can write the recipe from RWI to FLASH, reset after completion |
R/W |
|
60103 |
Recipe Download Instructions |
When the recipe is being written to the device, this bit is ON, and it is OFF after downloading |
R |
|
60104 |
Recipe upload instructions |
When the recipe is reading the device, this bit is ON, and it is OFF after downloading |
R |
|
60105 |
Restart the HMI |
Triggering this bit restarts the system |
R |
|
60106 |
Backlight Control |
Control this bit to ON to turn off the LCD backlight, OFF to turn on the LCD backlight |
R/W |
|
60107 |
COM1 communication status |
When ON, the communication is normal or there is no communication, and when OFF, the communication fails abnormally. |
R |
|
60108 |
COM2 communication status |
When ON, the communication is normal or there is no communication, and when OFF, the communication fails abnormally. |
R |
60186 |
COM3 communication status | When ON, the communication is normal or there is no communication, and when OFF, the communication fails abnormally. | R |
|
60109 |
COM1 communication parameter modification storage |
Triggering this bit can write the modified communication parameters into the FLASH storage area, and turns OFF after completion |
R/W |
|
60110 |
COM2 communication parameter modification storage |
Triggering this bit can write the modified communication parameters into the FLASH storage area, and turns OFF after completion |
R/W |
60187 |
COM3 communication parameter modification storage | Triggering this bit can write the modified communication parameters into the FLASH storage area, and turns OFF after completion | R |
|
60111 |
Confirmation and modification of system parameters |
Triggering this bit can write the modified system parameters into the FLASH storage area, and turns OFF after completion |
R/W |
|
60112 |
Communication exception window |
When ON, the exception window is allowed to pop up, and when OFF, the exception window is prohibited from popping up. |
R/W |
|
60113 |
mouse cursor control |
When ON, the mouse cursor appears, and when OFF, the cursor is disabled (only when using touch) |
R/W |
|
60114 |
USB connection status |
When ON, there is a USB device connected, and when OFF, no USB device is connected. |
R |
|
60116 |
touch sound |
Whether there is a sound when touched or clicked with the mouse |
R/W |
|
60117 |
alarm sound |
Is there a sound when an alarm occurs? |
R/W |
|
60118 |
Clear the historical alarm record |
The number of historical alarm records is cleared (automatic reset) |
R/W |
|
60119 |
Operation record clear |
The number of operation records is cleared (automatic reset) |
R/W |
|
60120 |
Clear historical data records |
Historical data record reset (automatic reset) |
R/W |
|
60121 |
Overload recipe |
Reload the recipe data of the current recipe serial number, this bit is ON, and it is OFF after reloading |
R/W |
|
60123 |
Save history alarms |
When ON, save historical alarm records to flash, and automatically OFF after saving |
R/W |
|
60124 |
save historical data |
When ON, save historical data to flash, and automatically OFF after saving |
R/W |
|
60127 |
Send historical alarm files to U disk |
Send historical alarm files to U disk, automatically OFF after sending |
R/W |
|
60128 |
Send historical data files to U disk |
Send historical data files to U disk, automatically OFF after sending |
R/W |
|
60129 |
Send current project to U disk |
Send the project file to the U disk, and automatically turn off after sending |
R/W |
|
60132 |
The current user login trigger bit |
When it is ON, the user logs in automatically and resets automatically after completion |
R/W |
|
60133 |
The current user is logged in and out |
When ON, cancels user login and automatically resets after completion |
R/W |
|
60141 |
There is a real-time alarm happening |
When a real-time alarm occurs, this bit is ON |
R |
|
60142 |
The system is in a screen saver state |
When in the screen saver state, this bit is ON |
R |
|
60143 |
Copy the operation record to the U disk |
When ON, send the operation record file to the U disk, and automatically OFF after sending |
R/W |
|
60145 |
Copy all recipes to U disk |
When ON, send the recipe file to the U disk, and automatically OFF after sending |
W |
|
60147 |
USB two-digit barcode scanner scan end mark |
When ON, triggers |
R/W |
|
60148 |
Import historical data from U disk trigger bit |
When ON, trigger; auto reset. The file name of historical data imported by this function must be hisdata+group number.csv, otherwise this function will be invalid. |
R/W |
|
60150 |
Export the specified ID recipe to the trigger bit of the U disk |
When ON, trigger; automatically reset |
R/W |
|
60152 |
Import the specified ID recipe from the U disk to the HMI trigger bit |
When ON, trigger; automatically reset |
R/W |
|
60154 |
Clear the specified ID recipe trigger bit |
When ON, trigger; automatically reset |
R/W |
|
60155 |
Override Recipe Trigger Bit |
When ON, trigger; automatically reset |
R/W |
|
60156 |
Recipe read and save trigger bits |
When ON, trigger; automatically reset |
R/W |
|
60163 |
Export recipes to USB stick by group |
When ON, trigger; automatically reset |
R/W |
|
60165 |
Ethernet communication identification |
ON: Normal communication OFF: Communication abnormal |
R |
|
60167 |
Scan U disk files |
When ON, trigger; automatic reset, scan the .csv files in the root directory and subdirectories of the U disk, and display them in a pop-up window for import and export of recipe files |
R/W |
|
60168 |
Export historical data to U disk in groups |
When ON, trigger; automatically reset, LW60408 sets the export history data group number |
R/W |
|
60169 |
Station number disable mode selection |
ON: Automatic mode OFF: Manual mode (default option) Automatic station number disabling and unlocking: When the touch screen uses the extended mode to communicate with multiple devices, a device fails and cannot communicate, the application program automatically disables the station number communication, and there is an automatic reconnection mechanism inside, when the device can communicate normally , automatically unblock, restore communication |
R/W |
|
60173 |
Controls whether the VNC function is enabled |
When ON, the VNC function is enabled; when OFF, the VNC function is disabled |
R/W |
|
60176 |
Check if a SIM card is inserted |
When ON, SIM card insertion is detected; when OFF, SIM card insertion is not detected |
R |
|
60177 |
Update HMI SN code information |
Triggered when ON, update HMI SN code information |
R/W |
|
60178 |
TCP communication parameter modification enable flag bit |
When using the standard mode to connect an Ethernet device, dynamically modify the IP, port number, station number and other parameters of the connected device, and the setting will take effect. For |
R/W |
|
60179 |
Dynamic password key modification enable flag |
Set dynamic password key, set to take effect, automatically reset, key setting address: LW63147 Data type: ASCII Length: 6 |
R/W |
|
60180 |
Recipe name change trigger bit |
LW63153 (ASCII input control, length 32), after the formula name is entered, this address will take effect and automatically reset after completion |
R/W |
|
60181 |
Dynamic password enable flag |
Set whether the dynamic password function is enabled |
R/W |
|
60182 |
Dynamic password expiration time setting flag |
Set the dynamic password expiration time, year, month, day, hour: LW63141 ~ 63146 Data type: 16-bit integer, setting the date set after the completion LB60182, set to take effect automatically reset |
R/W |
|
60183 |
Data in the power-off hold area is immediately stored as the trigger bit |
Q series touch screen by default, the data in the power-off hold area will be automatically stored for 1 minute. By setting this address, the data in the power-off hold area will be stored immediately and automatically reset. |
R/W |
|
60185 |
Buzzer sound when generating an alarm |
Whether or not the HMI makes a sound when it generates an alarm.When it is 0, no sound is emitted; when it is 1, the HMI emits a sound |
R/W |
|
60188 |
Whether to enable the recipe operation register |
Recipe operation register flag bit, when 0, can not perform any operation on the recipe; when 1, can perform other operations on the recipe |
R/W |
|
60189 |
Copy the currently selected recipe |
Function of copying the currently selected recipe, when it is 1, the copying operation will be executed, and it will be reset automatically after it is set to 1. |
R/W |
|
60190 |
Cut out the current recipe |
Cut off the current recipe, the recipe behind will be data migration, after this position 1 will be automatically reset |
R/W |
|
60191 |
Recipe Paste |
Replacing the copied and cut recipes with the current recipe will automatically reset the setting of 1. |
R/W |
|
60192 |
Insertion of formulas |
When set to 1, a new blank recipe will be inserted after the current recipe, and it will be reset automatically after set to 1. |
R/W |
|
60193 |
end insertion |
When this bit is 1, a new blank recipe is inserted at the end of the current recipe group, and will be reset automatically after being set to 1. |
R/W |
|
60194 |
Clearance formula |
A value of 1 will clear the current recipe, and it will be reset automatically after being set to 1. |
R/W |
|
60195 |
Search for recipe name |
Used with address LW63198, If the search recipe exists, it will directly jump and switch to the corresponding recipe,
if it does not, no change will occur, and it will be automatically set to 0 after use.
The existence of search results can be determined by the LW63197 search status display. |
R/W |
|
60197 |
All-in-one switching USB connection |
When using an all-in-one device, the connected USB port can be switched by this address, and will be switched when 1 |
R/W |
|
60198 |
Remote Unlock/Lock |
This address allows remote control of the device and unlocking or locking operation of the target device.0: Unlock the remote screen;
1: Lock the remote screen |
R/W |
|
60199 |
Is the module recognized |
According to the status of this address to check whether the currently connected module is successfully recognized, the successful connection is 1; the failure is displayed as 0 |
R |
|
60201 |
Domestic and international transmission channels |
Select the transmission channel to be used for the transmission operation, 0: China Mainland; 1: Hong Kong, China. |
R |
|
60202 |
HMI synchronized online clock |
Updates the online time to the HMI for use with the time zone setting bit
LW61286.Time update is performed when it is 1, trigger is valid |
R/W |
|
60203 |
Get the current position information of the HMI |
Displayed as a latitude and longitude representation, in conjunction with registers Longitude LW61291, and
Latitude LW61293 for use.When 1, the current position information is updated, and the trigger is valid. |
R/W |