8.2 P01 IO input parameter group

Code

Name

Set range

unit

value

Effective mode

Set method

Set mode

P01-00

Input signal not assigned default state

0~65535 (hexadecimal)

0~15 digit setting meaning:

0- servo enable,

1- fault reset

2- gain switch,

3- command switch

4- command direction switch

5- Internal command switch 0

6- Internal command switch 1

7- Internal command switch 2

8- Internal command switch 3

9- Operating mode switch 0

10- Operating Mode switch 1

11 -zero clamp,

12- pulse disable

13- Prohibit forward rotation,

14- Prohibit reverse rotation

15- Forward external torque limit

--

0

Stop and restart

Set anytime

Ordinary users

P01-01

Input signal not assigned default state

0~65535 (hexadecimal)

0~15 digit setting meaning:

0- Reverse external torque limit

1- jog forward rotation

2- jog reversal

3 -reserved,

4- reserved,

5-reserved,

6 -reserved

7 -electronic gear switch

8- torque command direction

9- Speed command direction

10- position command direction

11- Enable multi segment position operation

12- Cancel interrupt fixed length action

13- Reserved

14 origin signal

15- Origin Regression Trigger Signal

--

0

Stop and restart

Set anytime

Ordinary users

P01-02

Input signal not assigned default state

0~127 (hexadecimal)

0~6 digit setting meaning:

0 -interrupt fixed length prohibition

1- Emergency Stop

2- Position deviation clearing

3- Speed Limit Selection

4 pulse command prohibited

5- probe 1

6 -probe 2

--

0

Stop and restart

Set anytime

Ordinary users

P01-03

Input signal not assigned default state

reverse

--

0

Stop and restart

Set anytime

Ordinary users

P01-04

DI1 terminal function selection

0- No allocation

1-Servo Enable

2- Fault reset

3-Gain switch

4-command switch

5-command direction switch

6- Internal command switch 0

7-Internal command switch 1

8-Internal command switch 2

9-Internal command switch 3

10 -Operation mode switch 0

11- Operation mode switch 1

12- Zero Clamp

13- Pulse prohibition

14- Prohibition of forward

15- prohibition of reverse

16- switch of external torque limit for forward rotation

17- switch of external torque limit for reverse rotation

18- jog forward rotation

19- Jog reverse rotation

20- Reserved, 21- Reserved, 22- Reserved, 23- Reserved

24- Electronic gear switch

25- Direction of torque command

26- Speed command direction

27- Position Command Direction

28- Enable multi position operation

29- Cancel interrupt fixed length action

30-when P05-40=1, set the current position as the origin through DI30, and return to the set electrical zero point by triggering DI32

31- Origin signal

32- Origin regression trigger signal

33- Interruption fixed length prohibition

34- Emergency stop

35- Clearance of Position Deviation

36- Speed limit selection

37- Pulse command prohibited

38- Probe 1

39- Probe 2

--

1

Effective immediately

Stop setting

Ordinary users

P01-05

DI2 terminal function selection

0- No allocation

1-Servo Enable

2- Fault reset

3-Gain switch

4-command switch

5-command direction switch

6- Internal command switch 0

7-Internal command switch 1

8-Internal command switch 2

9-Internal command switch 3

10 Operation mode switch 0

11- Operation mode switch 1

12 Zero Clamp

13- Pulse prohibition

14- Prohibition of forward

15- Prohibition of reverse

16- switch of external torque limit for forward rotation

17- switch of external torque limit for reverse rotation

18 -jog forward

19- Jog reverse

20- Reserved

21- Reserved

22- Reserved

23- Reserved

24- Electronic gear switch

25- Direction of torque command

26- Speed command direction

27- Position Command Direction

28- Enable multi position operation

29- Cancel interrupt fixed length action

30- when P05-40=1, set the current position as the origin through DI30, and return to the set electrical zero point by triggering DI32

31- Origin signal

32- Origin regression trigger signal

33- Interruption fixed length prohibition

34- Emergency stop

35- Clearance of Position Deviation

36- Speed limit selection

37 -Pulse command prohibited

38- Probe 1

39 -Probe 2

--

2

Effective immediately

Stop setting

Ordinary users

P01-06

DI3 terminal function selection

0- No allocation

1-Servo Enable

2- Fault reset

3-Gain switch

4-command switch

5-command direction switch

6- Internal command switch 0

7-Internal command switch 1

8-Internal command switch 2

9-Internal command switch 3

10 Operation mode switch 0

11- Operation mode switch 1

12 Zero Clamp

13- Pulse prohibition

14- Prohibition of forward

15- Prohibition of reverse

16- switch of external torque limit for forward rotation

17- switch of external torque limit for reverse rotation

18 -jog forward

19- Jog reverse

20- Reserved, 21- Reserved, 22- Reserved, 23- Reserved

24- Electronic gear switch

25- Direction of torque command

26- Speed command direction

27- Position Command Direction

28- Enable multi position operation

29- Cancel interrupt fixed length action

30- when P05-40=1, set the current position as the origin through DI30, and return to the set electrical zero point by triggering DI32

31- Origin signal

32- Origin regression trigger signal

33- Interruption fixed length prohibition

34- Emergency stop

35- Clearance of Position Deviation

36- Speed limit selection

37 -Pulse command prohibited

38 -Probe 1

39- Probe 2

--

14

Effective immediately

Stop setting

Ordinary users

P01-07

DI4 terminal function selection

0- No allocation

1-Servo Enable

2- Fault reset

3-Gain switch

4-command switch

5-command direction switch

6- Internal command switch 0

7-Internal command switch 1

8-Internal command switch 2

9-Internal command switch 3

10 Operation mode switch 0

11- Operation mode switch 1

12 Zero Clamp

13- Pulse prohibition

14- Prohibition of forward

15- Prohibition of reverse

16- switch of external torque limit for forward rotation

17- switch of external torque limit for reverse rotation

18 -jog forward

19- Jog reverse

20- Reserved, 21- Reserved, 22- Reserved, 23- Reserved

24- Electronic gear switch

25- Direction of torque command

26- Speed command direction

27- Position Command Direction

28- Enable multi position operation

29- Cancel interrupt fixed length action

30- when P05-40=1, set the current position as the origin through DI30, and return to the set electrical zero point by triggering DI32

31- Origin signal

32- Origin regression trigger signal

33- Interruption fixed length prohibition

34- Emergency stop

35- Clearance of Position Deviation

36- Speed limit selection

37 -Pulse command prohibited

38- Probe 1

39- Probe 2

--

15

Effective immediately

Stop setting

Ordinary users

P01-20

DI1 terminal logic selection

0-Low effective (ON)

1. High effective (OFF)

2- Effective rising edge (ON ->OFF)

3- Effective falling edge (OFF ->ON)

4-Edge effective (ON<->OFF)

--

0

Effective immediately

Stop setting

Ordinary users

P01-21

DI2 terminal logic selection

0-Low effective (ON)

1. High effective (OFF)

2- Effective rising edge (ON ->OFF)

3- Effective falling edge (OFF ->ON)

4-Edge effective (ON<->OFF)

--

0

Effective immediately

Stop setting

Ordinary users

P01-22

DI3 terminal logic selection

0-Low effective (ON)

1. High effective (OFF)

2- Effective rising edge (ON ->OFF)

3- Effective falling edge (OFF ->ON)

4-Edge effective (ON<->OFF)

--

0

Effective immediately

Stop setting

Ordinary users

P01-23

DI4 terminal logic selection

0-Low effective (ON)

1. High effective (OFF)

2- Effective rising edge (ON ->OFF)

3- Effective falling edge (OFF ->ON)

4-Edge effective (ON<->OFF)

--

0

Effective immediately

Stop setting

Ordinary users

P01-43

Digital input filtering time

0~32

0

Restart to take effect

Stop setting

Ordinary users