8.8 P08 Analog Parameter Group
Code | Name | Set range | unit | value | Effective mode | Set method | Set mode |
|---|---|---|---|---|---|---|---|
P08-00 | Analog quantity 10V corresponds to speed | 0~6000 | rpm | 3000 | Effective immediately | Set anytime | Ordinary users |
P08-01 | Torque correspond to analog 10V | 0~300 | % | 100 | Effective immediately | Set anytime | Ordinary users |
P08-02 | AI1 offset | -32768~32767 | mv | 0 | Effective immediately | Set anytime | Ordinary users |
P08-03 | AI1 input filtering time | 0~65535 | 10us | 200 | Effective immediately | Set anytime | Ordinary users |
P08-04 | AI1 Input value Filter Enable | 0-Disability 1- Enable | -- | 1 | Effective immediately | Set anytime | Ordinary users |
P08-05 | AI1 Dead Zone | -32768~32767 | 0.1mv | 100 | Effective immediately | Set anytime | Ordinary users |
P08-06 | AI1 zero drift | -32768~32767 | 0.1mv | 0 | Effective immediately | Set anytime | Ordinary users |
P08-07 | AI2 offset | -32768~32767 | mv | 0 | Effective immediately | Set anytime | Ordinary users |
P08-08 | AI2 input filtering time | 0~65535 | 10us | 200 | Effective immediately | Set anytime | Ordinary users |
P08-09 | AI2 Input value Filter Enable | 0-Disability 1- Enable | -- | 1 | Effective immediately | Set anytime | Ordinary users |
P08-10 | AI2 Dead Zone | -32768~32767 | 0.1mv | 100 | Effective immediately | Set anytime | Ordinary users |
P08-11 | AI2 zero drift | -32768~32767 | 0.1mv | 0 | Effective immediately | Set anytime | Ordinary users |