8.5 P05 Position Control Parameter Group
Code | Name | Set range | unit | value | Effective mode | Set method | Set mode |
|---|---|---|---|---|---|---|---|
P05-00 | Single cycle pulse count | 0~1048576 | P/REV | 10000 | Stop and restart | Stop setting | Ordinary users |
P05-02 | Electronic gear ratio of 1 molecule | 1~1073741824 | -- | 1 | Effective immediately | Set anytime | Ordinary users |
P05-04 | Electronic gear ratio 1 denominator | 1~1073741824 | -- | 1 | Effective immediately | Set anytime | Ordinary users |
P05-06 | Electronic gear ratio 2 molecules | 1~1073741824 | -- | 1 | Effective immediately | Set anytime | Ordinary users |
P05-08 | Electronic gear ratio 2 denominator | 1~1073741824 | -- | 1 | Effective immediately | Set anytime | Ordinary users |
P05-14 | Electronic gear switch enable | 0~1 | -- | 0 | Effective immediately | Stop setting | Ordinary users |
P05-15 | Location command source | 0-Low speed pulse input 1. High speed pulse input 2-Division output OA, OB signals 3- Constant at 0 4- Internal multi-stage pulse input | -- | 0 | Effective immediately | Stop setting | Ordinary users |
P05-16 | Command pulse form | 0-pulse+direction 1-AB phase x4 2-CW+CCW 3-AB phase x1 | -- | 0 | Stop and restart | Stop setting | Ordinary users |
P05-17 | Reverse phase of command pulse signal | 0-pulse, sign are not reversed 1-pulse inversion, sign non inversion 2-pulse not reversed, sign reversed 3-pulse inversion, sign inversion | -- | 0 | Stop and restart | Stop setting | Ordinary users |
P05-18 | Pulse signal filtering time | 0~255 | 20ns | 25 | Stop and restart | Stop setting | Ordinary users |
P05-19 | Direction signal input filtering time | 0~255 | 20ns | 25 | Stop and restart | Stop setting | Ordinary users |
P05-20 | Position command filtering time | 0~65535 | 0.1ms | 0 | Effective immediately | Stop setting | Ordinary users |
P05-21 | Position command speed calculation filtering time | 0~1280 | 0.1ms | 0 | Effective immediately | Stop setting | Ordinary users |
P05-22 | Location unit setting | 0-Encoder unit 1- command Unit | -- | 1 | Stop and restart | Set anytime | Ordinary users |
P05-25 | Selection of pulse output source | 0-Encoder allocation output 1-command pulse synchronous output 2- No output 3-Parameter trigger, starting output from P5-35, outputting P5-34 set number of pulses | -- | 0 | Stop and restart | Stop setting | Ordinary users |
P05-26 | Pulse frequency division output phase | 0-A ahead of B 1-B ahead of A | -- | 0 | Stop and restart | Stop setting | Ordinary users |
P05-27 | Z-pulse output effective level | 0- High current effective 1- Low current effective | -- | 1 | Stop and restart | Stop setting | Ordinary users |
P05-28 | Single phase maximum frequency of pulse output | 1~25000 | KHz | 1000 | Effective immediately | Set anytime | Ordinary users |
P05-29 | Single phase minimum frequency of pulse output | 1~25000 | KHz | 50 | Effective immediately | Set anytime | Ordinary users |
P05-30 | Pulse output single-phase pulse count | 0~0xFFFFFFFF | P | 2500 | Stop and restart | Stop setting | Ordinary users |
P05-32 | Pulse output signal type | 0-AB phase x4 1-Pulse+Direction 2-CW+CCW 3-AB phase x1 | -- | 0 | Effective immediately | Set anytime | Ordinary users |
P05-33 | Default logic current for pulse output | 0-A is low, B is low 1-A is high, B is low 2-A is low, B is high 3-A is high, B is high | -- | 0 | Stop and restart | Set anytime | Ordinary users |
P05-34 | Number of single pulse outputs | -32768~32767 | P | 0 | Effective immediately | Set anytime | R&D personnel |
P05-35 | Pulse output single trigger | 0~1 | -- | 0 | Effective immediately | Set anytime | R&D engineer |
P05-36 | Pulse output counting | -2147483648~2147483647 | P | 0 | read-only | read-only | Ordinary users |
P05-38 | Pulse output execution mode | 0-high synchronization mode, with small pulse output lag and large output frequency fluctuations 1-Stable mode, with stable pulse output frequency but large lag | -- | 0 | Stop and restart | Set anytime | Ordinary users |
P05-39 | Z-pulse dead time | 0~30000 | 0.0001 | 3 | Stop and restart | Set anytime | Ordinary users |
P05-40 | Origin reset enable | 0-Close Origin Reset 1. Enable the origin reset function through DI input ORGSET signal 2. Enable electrical zeroing function by inputting ORGSET signal through DI 3. Immediately start the origin reset after power on 4. Immediately reset the origin point 5. Immediately set electrical zeroing 6- Using the current position as the origin | -- | 0 | Effective immediately | Set anytime | Ordinary users |
P05-41 | Origin reset mode | 0-Forward return to zero, deceleration point is the origin switch 1. Reverse to zero, deceleration point is the origin switch 2- Forward return to zero, deceleration point is Z signal 3- Reverse to zero, deceleration point is Z signal 4- Forward return to zero, deceleration point is the origin switch signal, origin is the Z signal 5- Reverse to zero, deceleration point is the origin switch signal, origin is the Z signal 6-Forward return to zero, deceleration point and origin are forward limit switches 7-Reverse return to zero, deceleration point and origin are reverse limit switches 8-Forward return to zero, deceleration point is forward limit switch, origin is Z signal 9-Reverse return to zero, deceleration point is reverse limit switch, origin is Z signal 10-When P05-40=1, the current position can be set as the origin through DI triggering (32) | -- | 0 | Effective immediately | Stop setting | Ordinary users |
P05-42 | Origin high-speed search speed | 0~3000 | rpm | 100 | Effective immediately | Set anytime | Ordinary users |
P05-43 | Origin low-speed search speed | 0~1000 | rpm | 10 | Effective immediately | Set anytime | Ordinary users |
P05-44 | Origin acceleration and deceleration time | 0~1000 | ms | 1000 | Effective immediately | Set anytime | Ordinary users |
P05-45 | Origin search time | 0~65535 | ms | 50000 | Effective immediately | Set anytime | Ordinary users |
P05-46 | Origin offset and limit handling methods | 0~3 (by bit) 0- Is the origin offset 1- Does it reverse zeroing when encountering a limit switch | 0 | 0 | Effective immediately | Stop setting | Ordinary users |
P05-48 | Origin mechanical offset | -1073741824~1073741824 | ins | 0 | Effective immediately | Set anytime | Ordinary users |
P05-50 | Position deviation clearing action | 0- clearing position deviation count when Servo off and malfunction 1-Clear the position deviation count when a malfunction occurs 2- Clear position deviation count through CLR signal | -- | 0 | Effective immediately | Stop setting | Ordinary users |
P05-51 | Positioning completion signal COIN output conditions | 0-Output when the absolute value of position deviation is less than the positioning completion threshold (bus type is object dictionary 6067h) 1-When the absolute value of position deviation is less than the positioning completion threshold (bus type is object dictionary 6067h) and after filtered position command is 0, output 2-When the absolute value of the position deviation is less than the positioning completion threshold (bus type is object dictionary 6067h) and before filtered position command is 0, output | -- | 0 | Effective immediately | Set anytime | Ordinary users |
P05-52 | Positioning completion threshold | 1~65535 | ins | 1 | Effective immediately | Set anytime | Ordinary users |
P05-53 | Positioning completed approaching signal threshold | 1~65535 | ins | 10000 | Effective immediately | Set anytime | Ordinary users |
P05-54 | Positioning completion retention time | 0~30000 | ms | 0 | Effective immediately | Set anytime | Ordinary users |
P05-56 | Multi cycle absolute position offset low by 32 bits | 0~1073741824 | P | 0 | Effective immediately | Stop setting | Ordinary users |
P05-58 | Multi cycle absolute position offset high by 32 bits | 0~1073741824 | P | 0 | Effective immediately | Stop setting | Ordinary users |
P05-60 | Encoder multi cycle data bias | 0~65535 | P | 0 | Effective immediately | Stop setting | Ordinary users |
P05-61 | Multi cycle absolute position mode 2 mechanical gear ratio molecule | 1~65535 | -- | 1 | Effective immediately | Stop setting | Ordinary users |
P05-62 | Multi cycle absolute position mode 2 mechanical gear ratio denominator | 1~65535 | -- | 1 | Effective immediately | Stop setting | Ordinary users |
P05-64 | Multi cycle absolute position mode 2 mechanical absolute position upper limit value (low) | 0~1073741824 | P | 0 | Effective immediately | Stop setting | Ordinary users |
P05-66 | Multi cycle absolute position mode 2 mechanical absolute position upper limit value (high) | 0~1073741824 | P | 0 | Effective immediately | Stop setting | Ordinary users |
P05-76 | Z-signal pulse width | 0~1000 | 250us | 8 (default 2ms) | Stop and restart | Stop setting | Ordinary users |