8.16 P11 Driver Parameter Group

Code

Name

Set range

unit

value

Effective mode

Set method

Set mode

P11-00

Driver model

  1. R8-2202P

3- R8-2204P

5- R8-2208P

6- R8-2210P

7- R8-2215P

8- R8-2230P

2- R8-2202N

3- R8-2204N

5- R8-2208N

6- R8-2210N

7- R8-2215N

8- R8-2230N

--

five

Stop and restart

Stop setting

R&D personnel

P11-02

Rated voltage

0~65535

V

220

read-only

read-only

Manufacturer mode

P11-03

Rated power

1~65535

10W

75

read-only

read-only

Manufacturer mode

P11-04

Rated current

1~65535

0.01A

550

read-only

read-only

Manufacturer mode

P11-05

Maximum current

1~65535

0.01A

1690

read-only

read-only

Manufacturer mode

P11-06

Bus under voltage threshold

0~900

V

200

Stop and restart

Stop setting

Manufacturer mode

P11-07

Bus over voltage voltage threshold

0~900

V

395

Stop and restart

Stop setting

Manufacturer mode

P11-08

Bus voltage discharge threshold

0~900

V

375

Stop and restart

Stop setting

Manufacturer mode

P11-09

Dead Time

1~2000

0.01us

200

Stop and restart

Stop setting

Manufacturer mode

P11-10

Dead zone compensation amount

0~2000

0.01us

200

Stop and restart

Set anytime

Manufacturer mode

P11-11

Dead zone compensation inflection point

0~2000

0.01A

20

Stop and restart

Set anytime

Manufacturer mode

P11-12

Minimum duration of zero vector

0~6250

0.01us

960

Stop and restart

Set anytime

R&D personnel

P11-13

Enable local mode

0~1

--

0

Effective immediately

Stop setting

Ordinary users

P11-14

Current loop D-axis gain Kp

0~65535

--

2000

Effective immediately

Set anytime

Manufacturer mode

P11-15

Integral coefficient Ki of current loop D-axis

0~65535

Q7

256

Effective immediately

Set anytime

Manufacturer mode

P11-16

Current loop Q-axis gain Kp

0~65535

--

2000

Effective immediately

Set anytime

Manufacturer mode

P11-17

Current loop Q-axis integral coefficient Ki

0~65535

Q7

128

Effective immediately

Set anytime

Manufacturer mode

P11-18

Current loop D-axis gain Kp2

0~65535

--

1000

Effective immediately

Set anytime

Manufacturer mode

P11-19

Integration coefficient Ki2 of current loop D-axis

0~65535

Q7

200

Effective immediately

Set anytime

Manufacturer mode

P11-20

Current loop Q-axis gain Kp2

0~65535

--

1000

Effective immediately

Set anytime

Manufacturer mode

P11-21

Current loop Q-axis integral coefficient Ki2

0~65535

Q7

100

Effective immediately

Set anytime

Manufacturer mode

P11-22

Current loop gain coefficient Kp2Cef

0~10000

Q10

1024

Effective immediately

Set anytime

Manufacturer mode

P11-23

Current loop gain coefficient Kp3Coef

0~10000

Q10

1024

Effective immediately

Set anytime

Manufacturer mode

P11-24

Current loop gain switch point 1 current

0~3000

10

Effective immediately

Set anytime

Manufacturer mode

P11-25

Current loop gain switch point 2 current

0~3000

20

Effective immediately

Set anytime

Manufacturer mode

P11-26

Current loop gain switch point 3 current

0~3000

1000

Effective immediately

Set anytime

Manufacturer mode

P11-27

Current loop gain switch point 4 current

0~3000

2000

Effective immediately

Set anytime

Manufacturer mode

P11-28

D-axis back electromotive force compensation coefficient

0~65535

0.1%

600

Effective immediately

Set anytime

Manufacturer mode

P11-29

Q-axis back electromotive force compensation coefficient

0~65535

0.1%

1000

Effective immediately

Set anytime

Manufacturer mode

P11-30

Voltage decoupling resistance effect failure

0-Enable

1- Disability

--

0

Stop and restart

Set anytime

Manufacturer mode

P11-31

Voltage decoupling inductance effect failure

0-Enable

1- Disability

--

0

Stop and restart

Set anytime

Manufacturer mode

P11-32

Voltage decoupling back electromotive force effect incapacitation

0-Enable

1- Disability

--

0

Stop and restart

Set anytime

Manufacturer mode

P11-33

Voltage decoupling disabling control

0-Enable

1- Disability

--

0

Stop and restart

Set anytime

Manufacturer mode

P11-34

Maximum sampling current

1~65535

0.01A

1200

Stop and restart

Set anytime

R&D personnel

P11-35

Phase overcurrent detection threshold

0~10000

0.01A

1800

Stop and restart

Set anytime

Manufacturer mode

P11-36

UVW over current detection filtering time

0~60000

0.1us

96

Stop and restart

Set anytime

Manufacturer mode

P11-37

Power failure detection mode

0-Bus phase loss detection

1. Control voltage detection

--

0

Effective immediately

Set anytime

R&D personnel

P11-38

Single phase electrical input allowed

0- Prohibited

1- Allow

--

0

Stop and restart

Set anytime

R&D personnel

P11-39

FOC calculation time

100~10000

0.01us

260

Stop and restart

Set anytime

R&D personnel

P11-40

MCU current command processing time

0~6000

0.01us

5500

Stop and restart

Set anytime

R&D personnel

P11-41

Bus encoder data transmission compensation time

0~1000

0.01us

0

Stop and restart

Set anytime

R&D personnel

P11-42

Absolute encoder command transmission interval

0~65535

--

3120

Stop and restart

Set anytime

R&D personnel

P11-47

Minimum allowable energy consumption resistance of the driver

1~1000

Ω

40

Stop and restart

Set anytime

R&D personnel

P11-48

Built in energy consumption resistor, power capacity

1~65535

W

40

Stop and restart

Set anytime

R&D personnel

P11-49

Built in energy consumption resistor resistance value

1~1000

Ω

50

Stop and restart

Set anytime

R&D personnel

P11-50

Resistance heat dissipation coefficient

10~100

--

30

Stop and restart

Stop setting

Manufacturer mode

P11-51

Maximum regeneration time

0~30000

ms

3000

Stop and restart

Set anytime

Manufacturer mode

P11-52

carrier frequency

4000~20000

Hz

8000

Stop and restart

Set anytime

R&D personnel

P11-53

Current sampling mode

0-Trigger Sampling

1- Continuous sampling

--

0

Stop and restart

Set anytime

R&D personnel

P11-54

PWM immediate update enable

0- Not enabled, updated twice per carrier wave period

1- Enable, update immediately

--

1

Stop and restart

Set anytime

R&D personnel

P11-55

Frequency selection for current loop modulation

0~1

--

0

Stop and restart

Set anytime

R&D personnel

P11-56

Speed loop scheduling frequency division coefficient

0-The current loop and carrier frequency are consistent

1-The current loop frequency is twice the carrier frequency

--

1

Stop and restart

Set anytime

R&D personnel

P11-57

Frequency division coefficient for position loop scheduling

2~128

--

4

Stop and restart

Set anytime

R&D personnel

P11-58

Maximum allowable duration of et1100 NWAIT signal

0~204

0.1us

12

Stop and restart

Set anytime

R&D personnel

P11-59

Driver load rate filtering time constant

0~10000

0.1s

300

Stop and restart

Set anytime

R&D personnel

P11-76

Enable bus voltage filtering

0

0

Effective immediately

Set anytime

R&D personnel

P11-77

Number of bus voltage filtering cycles

1~20

125us

1

Restart to take effect

Stop setting

R&D personnel