8.18 P13 Monitoring Parameter Group
Code | Name | Set range | unit | value | Effective mode | Set method | Set mode |
|---|---|---|---|---|---|---|---|
P13-00 | Servo operation status | 0-Servo not ready 1- Servo ready 2- Servo operation 3- Servo malfunction | -- | 0 | read-only | read-only | Ordinary users |
P13-01 | Alarm ID | 0~65535 | -- | 0 | read-only | read-only | Ordinary users |
P13-02 | motor speed | -32767~32767 | rpm | 0 | read-only | read-only | Ordinary users |
P13-03 | Speed command | -32767~32767 | rpm | 0 | read-only | read-only | Ordinary users |
P13-04 | Torque command | -32767~32767 | ‰ | 0 | read-only | read-only | Ordinary users |
P13-05 | Torque feedback | -32767~32767 | ‰ | 0 | read-only | read-only | Ordinary users |
P13-10 | Command pulse counting | -2147483648~2147483647 | ins | 0 | read-only | read-only | Ordinary users |
P13-12 | Input pulse count | -2147483648~2147483647 | ins | 0 | read-only | read-only | Ordinary users |
P13-14 | Feedback pulse counting | -2147483648~2147483647 | p | 0 | read-only | read-only | Ordinary users |
P13-16 | Position deviation (command unit) | -2147483648~2147483647 | ins | 0 | read-only | read-only | Ordinary users |
P13-18 | Position deviation (encoder unit) | -2147483648~2147483647 | p | 0 | read-only | read-only | Ordinary users |
P13-20 | Command pulse speed | -32767~32767 | rpm | 0 | read-only | read-only | Ordinary users |
P13-21 | Bus voltage | -32767~32767 | 0.1V | 0 | read-only | read-only | Ordinary users |
P13-22 | Control the bus voltage | 0~65535 | 0.1V | 0 | read-only | read-only | Ordinary users |
P13-23 | Phase current | 0~65535 | 0.01A | 0 | read-only | read-only | Ordinary users |
P13-24 | Effective value of driver output line voltage | 0~65535 | 0.1V | 0 | read-only | read-only | Ordinary users |
P13-25 | Driver temperature | 0~65535 | 0.1℃ | 0 | read-only | read-only | Ordinary users |
P13-26 | IGBT temperature | 0~2000 | 0.1℃ | 0 | read-only | read-only | Ordinary users |
P13-27 | Driver load rate | 0~10000 | ‰ | 0 | read-only | read-only | Ordinary users |
P13-28 | Motor load rate | 0~8000 | ‰ | 0 | read-only | read-only | Ordinary users |
P13-29 | Input signal monitoring DI | 0~65535 | -- | 0 | read-only | read-only | Ordinary users |
P13-30 | Output signal monitoring DO | 0~65535 | -- | 0 | read-only | read-only | Ordinary users |
P13-31 | Electrical angle | 0~3600 | 0.1° | 0 | read-only | read-only | Ordinary users |
P13-32 | Encoder single turn position | -2147483648~2147483647 | p | 0 | read-only | read-only | Ordinary users |
P13-34 | Encoder multi turn position | 0~65535 | circle | 0 | read-only | read-only | Ordinary users |
P13-36 | Mechanical absolute position counting (command unit) | -2147483648~2147483647 | ins | 0 | read-only | read-only | Ordinary users |
P13-38 | Mechanical absolute position is low 32 bits (encoder unit) | -2147483648~2147483647 | p | 0 | read-only | read-only | Ordinary users |
P13-40 | Mechanical absolute position is high 32 bits (encoder unit) | -2147483648~2147483647 | p | 0 | read-only | read-only | Ordinary users |
P13-42 | Rotating load single turn position (command unit) | 0~2147483647 | ins | 0 | read-only | read-only | Ordinary users |
P13-44 | Rotating load single turn position is low 32 bits (encoder unit) | 0~2147483647 | p | 0 | read-only | read-only | Ordinary users |
P13-46 | Rotating load single turn position is high 32 bits (encoder unit) | 0~2147483647 | p | 0 | read-only | read-only | Ordinary users |
P13-48 | Encoder position is low by 32 bits | -2147483648~2147483647 | p | 0 | read-only | read-only | Ordinary users |
P13-50 | Encoder position is high 32 bits | -2147483648~2147483647 | p | 0 | read-only | read-only | Ordinary users |
P13-52 | AI1 sampling voltage | -32767~32767 | mV | 0 | read-only | read-only | Ordinary users |
P13-53 | AI2 sampling voltage | -32767~32767 | mV | 0 | read-only | read-only | Ordinary users |
P13-54 | AI3 sampling voltage | -32767~32767 | mV | 0 | read-only | read-only | Ordinary users |
P13-55 | Load inertia ratio | 0~65535 | % | 0 | read-only | read-only | Ordinary users |
P13-56 | External load torque | -1000~1000 | ‰ | 0 | read-only | read-only | Ordinary users |
P13-57 | Fault record index | 0~9 | -- | 0 | read-only | read-only | Ordinary users |
P13-58 | Fault code | 0~65535 | -- | 0 | read-only | read-only | Ordinary users |
P13-60 | Selected fault timestamp low bit | 0~2147483647 | 0.1s | 0 | read-only | read-only | Ordinary users |
P13-62 | Speed at selected fault | -32767~32767 | rpm | 0 | read-only | read-only | Ordinary users |
P13-63 | U-phase current during selected fault | -32767~32767 | 0.01A | 0 | read-only | read-only | Ordinary users |
P13-64 | V-phase current during selected fault | -32767~32767 | 0.01A | 0 | read-only | read-only | Ordinary users |
P13-65 | Bus voltage at selected fault | 0~65535 | 0.1V | 0 | read-only | read-only | Ordinary users |
P13-66 | Input terminal status when selecting faults | 0~65535 | -- | 0 | read-only | read-only | Ordinary users |
P13-67 | Output terminal status at selected fault | 0~65535 | -- | 0 | read-only | read-only | Ordinary users |
P13-68 | Command speed at selected fault | -30000~30000 | rpm | 0 | read-only | read-only | Ordinary users |
P13-69 | Command torque for selected faults | -30000~30000 | ‰ | 0 | read-only | read-only | Ordinary users |
P13-70 | Feedback torque for selected faults | -30000~30000 | ‰ | 0 | read-only | read-only | Ordinary users |
P13-71 | Position command for selected fault | -32767~32767 | p | 0 | read-only | read-only | Ordinary users |
P13-72 | Position deviation during selected fault | -32767~32767 | p | 0 | read-only | read-only | Ordinary users |
P13-73 | Control word for selected fault | 0~65535 | -- | 0 | read-only | read-only | Ordinary users |
P13-74 | Status word for selected fault | 0~65535 | -- | 0 | read-only | read-only | Ordinary users |
P13-77 | Number of effective faults | 0~65535 | -- | 0 | read-only | read-only | Ordinary users |
P13-78 | Function code group number with abnormal parameters | 0~65535 | -- | 0 | read-only | read-only | Ordinary users |
P13-79 | Function code group offset with abnormal parameters | 0~65535 | -- | 0 | read-only | read-only | Ordinary users |
P13-80 | Total running time | 0~2147483647 | 0.1s | 0 | read-only | read-only | Ordinary users |
P13-91 | Maximum scheduling time for the main loop within 4 seconds | 0~65535 | us | 0 | read-only | read-only | R&D personnel |
P13-92 | Maximum running time of the main loop within 4 seconds | 0~65535 | us | 0 | read-only | read-only | R&D personnel |
P13-93 | Maximum interruption running time of current loop within 4 seconds | 0~65535 | us | 0 | read-only | read-only | R&D personnel |
P13-94 | Maximum interruption running time of the position loop within 4 seconds | 0~65535 | us | 0 | read-only | read-only | R&D personnel |