8.18 P13 Monitoring Parameter Group

Code

Name

Set range

unit

value

Effective mode

Set method

Set mode

P13-00

Servo operation status

0-Servo not ready

1- Servo ready

2- Servo operation

3- Servo malfunction

--

0

read-only

read-only

Ordinary users

P13-01

Alarm ID

0~65535

--

0

read-only

read-only

Ordinary users

P13-02

motor speed

-32767~32767

rpm

0

read-only

read-only

Ordinary users

P13-03

Speed command

-32767~32767

rpm

0

read-only

read-only

Ordinary users

P13-04

Torque command

-32767~32767

0

read-only

read-only

Ordinary users

P13-05

Torque feedback

-32767~32767

0

read-only

read-only

Ordinary users

P13-10

Command pulse counting

-2147483648~2147483647

ins

0

read-only

read-only

Ordinary users

P13-12

Input pulse count

-2147483648~2147483647

ins

0

read-only

read-only

Ordinary users

P13-14

Feedback pulse counting

-2147483648~2147483647

p

0

read-only

read-only

Ordinary users

P13-16

Position deviation (command unit)

-2147483648~2147483647

ins

0

read-only

read-only

Ordinary users

P13-18

Position deviation (encoder unit)

-2147483648~2147483647

p

0

read-only

read-only

Ordinary users

P13-20

Command pulse speed

-32767~32767

rpm

0

read-only

read-only

Ordinary users

P13-21

Bus voltage

-32767~32767

0.1V

0

read-only

read-only

Ordinary users

P13-22

Control the bus voltage

0~65535

0.1V

0

read-only

read-only

Ordinary users

P13-23

Phase current

0~65535

0.01A

0

read-only

read-only

Ordinary users

P13-24

Effective value of driver output line voltage

0~65535

0.1V

0

read-only

read-only

Ordinary users

P13-25

Driver temperature

0~65535

0.1℃

0

read-only

read-only

Ordinary users

P13-26

IGBT temperature

0~2000

0.1℃

0

read-only

read-only

Ordinary users

P13-27

Driver load rate

0~10000

0

read-only

read-only

Ordinary users

P13-28

Motor load rate

0~8000

0

read-only

read-only

Ordinary users

P13-29

Input signal monitoring DI

0~65535

--

0

read-only

read-only

Ordinary users

P13-30

Output signal monitoring DO

0~65535

--

0

read-only

read-only

Ordinary users

P13-31

Electrical angle

0~3600

0.1°

0

read-only

read-only

Ordinary users

P13-32

Encoder single turn position

-2147483648~2147483647

p

0

read-only

read-only

Ordinary users

P13-34

Encoder multi turn position

0~65535

circle

0

read-only

read-only

Ordinary users

P13-36

Mechanical absolute position counting (command unit)

-2147483648~2147483647

ins

0

read-only

read-only

Ordinary users

P13-38

Mechanical absolute position is low 32 bits (encoder unit)

-2147483648~2147483647

p

0

read-only

read-only

Ordinary users

P13-40

Mechanical absolute position is high 32 bits (encoder unit)

-2147483648~2147483647

p

0

read-only

read-only

Ordinary users

P13-42

Rotating load single turn position (command unit)

0~2147483647

ins

0

read-only

read-only

Ordinary users

P13-44

Rotating load single turn position is low 32 bits (encoder unit)

0~2147483647

p

0

read-only

read-only

Ordinary users

P13-46

Rotating load single turn position is high 32 bits (encoder unit)

0~2147483647

p

0

read-only

read-only

Ordinary users

P13-48

Encoder position is low by 32 bits

-2147483648~2147483647

p

0

read-only

read-only

Ordinary users

P13-50

Encoder position is high 32 bits

-2147483648~2147483647

p

0

read-only

read-only

Ordinary users

P13-52

AI1 sampling voltage

-32767~32767

mV

0

read-only

read-only

Ordinary users

P13-53

AI2 sampling voltage

-32767~32767

mV

0

read-only

read-only

Ordinary users

P13-54

AI3 sampling voltage

-32767~32767

mV

0

read-only

read-only

Ordinary users

P13-55

Load inertia ratio

0~65535

%

0

read-only

read-only

Ordinary users

P13-56

External load torque

-1000~1000

0

read-only

read-only

Ordinary users

P13-57

Fault record index

0~9

--

0

read-only

read-only

Ordinary users

P13-58

Fault code

0~65535

--

0

read-only

read-only

Ordinary users

P13-60

Selected fault timestamp low bit

0~2147483647

0.1s

0

read-only

read-only

Ordinary users

P13-62

Speed at selected fault

-32767~32767

rpm

0

read-only

read-only

Ordinary users

P13-63

U-phase current during selected fault

-32767~32767

0.01A

0

read-only

read-only

Ordinary users

P13-64

V-phase current during selected fault

-32767~32767

0.01A

0

read-only

read-only

Ordinary users

P13-65

Bus voltage at selected fault

0~65535

0.1V

0

read-only

read-only

Ordinary users

P13-66

Input terminal status when selecting faults

0~65535

--

0

read-only

read-only

Ordinary users

P13-67

Output terminal status at selected fault

0~65535

--

0

read-only

read-only

Ordinary users

P13-68

Command speed at selected fault

-30000~30000

rpm

0

read-only

read-only

Ordinary users

P13-69

Command torque for selected faults

-30000~30000

0

read-only

read-only

Ordinary users

P13-70

Feedback torque for selected faults

-30000~30000

0

read-only

read-only

Ordinary users

P13-71

Position command for selected fault

-32767~32767

p

0

read-only

read-only

Ordinary users

P13-72

Position deviation during selected fault

-32767~32767

p

0

read-only

read-only

Ordinary users

P13-73

Control word for selected fault

0~65535

--

0

read-only

read-only

Ordinary users

P13-74

Status word for selected fault

0~65535

--

0

read-only

read-only

Ordinary users

P13-77

Number of effective faults

0~65535

--

0

read-only

read-only

Ordinary users

P13-78

Function code group number with abnormal parameters

0~65535

--

0

read-only

read-only

Ordinary users

P13-79

Function code group offset with abnormal parameters

0~65535

--

0

read-only

read-only

Ordinary users

P13-80

Total running time

0~2147483647

0.1s

0

read-only

read-only

Ordinary users

P13-91

Maximum scheduling time for the main loop within 4 seconds

0~65535

us

0

read-only

read-only

R&D personnel

P13-92

Maximum running time of the main loop within 4 seconds

0~65535

us

0

read-only

read-only

R&D personnel

P13-93

Maximum interruption running time of current loop within 4 seconds

0~65535

us

0

read-only

read-only

R&D personnel

P13-94

Maximum interruption running time of the position loop within 4 seconds

0~65535

us

0

read-only

read-only

R&D personnel