8.7 P07 Torque Control Parameter Group
Code | Name | Set range | unit | value | Effective mode | Set method | Set mode |
|---|---|---|---|---|---|---|---|
P07-00 | Torque command selection | 0-Torque command A 1- Torque command B 2-Torque command A+torque command B 3- Torque command A/B, switchable 4- Communication Given (P31-10) | -- | 0 | Effective immediately | Stop setting | Ordinary users |
P07-01 | Source of torque command A | 0-Internal number given (P7-03) 1- Analog Channel 1 Input (AI1) 2- Analog Channel 2 Input (AI2) | -- | 0 | Effective immediately | Stop setting | Ordinary users |
P07-02 | Source of torque command B | 0-Internal number given (P7-03) 1- Analog Channel 1 Input (AI1) 2- Analog Channel 2 Input (AI2) | -- | 0 | Effective immediately | Stop setting | Ordinary users |
P07-03 | Torque command keyboard setting | -3000~3000 | ‰ | 0 | Effective immediately | Set anytime | Ordinary users |
P07-04 | Source of torque limitation | 0-Internal torque limit, using P7-05 and P7-06 limits 1-Torque limit switchable forward torque limit: P-CL selects P7-05/P7-07 Reverse torque limit: N-CL selects P7-06/P7-08 2- Use analog/object dictionary to limit torque 3- Use analog/object dictionary to limit torque, P-CL, N-CL control whether to enable external torque limits P7-07, P7-08 respectively. If external torque limits are enabled, take the smaller of analog and external torque as the limit 4-Torque limit switchable forward torque limit: P-CL selects P7-04/Analog (Ethercat) Reverse torque limit: N-CL selects P7-05/Analog (Ethercat) | -- | 0 | Effective immediately | Set anytime | Ordinary users |
P07-05 | Internal torque limit value for forward rotation | 0~3000 | ‰ | 3000 | Effective immediately | Set anytime | Ordinary users |
P07-06 | Reverse internal torque limit value | 0~3000 | ‰ | 3000 | Effective immediately | Set anytime | Ordinary users |
P07-07 | External torque limit value on the forward rotation side | 0~3000 | ‰ | 3000 | Effective immediately | Set anytime | Ordinary users |
P07-08 | Reverse side external torque limit value | 0~3000 | ‰ | 3000 | Effective immediately | Set anytime | Ordinary users |
P07-09 | Torque command filter time 1 | 0~3000 | 10us | 79 | Effective immediately | Set anytime | Ordinary users |
P07-10 | Torque command filter time 2 | 0~3000 | 10us | 79 | Effective immediately | Set anytime | Ordinary users |
P07-11 | Emergency stop torque | 0~3000 | ‰ | 1000 | Effective immediately | Stop setting | Ordinary users |
P07-12 | Speed limit source selection | 0-Internal speed limit, P7-13 and P7-14 1-Pulse type: using AI limit; Bus type: using 607Fh value limit 2. The forward and reverse speed limits are the same, use V-SEL to select the limit values P7-13/P7-14 | -- | 1 | Effective immediately | Set anytime | Ordinary users |
P07-13 | Internal speed forward limit value during torque control | 0~6000 | rpm | 3000 | Effective immediately | Set anytime | Ordinary users |
P07-14 | Internal speed reverse limit value during g torque control | 0~6000 | rpm | 3000 | Effective immediately | Set anytime | Ordinary users |
P07-15 | The torque reaches the reference value | 0~3000 | ‰ | 0 | Effective immediately | Set anytime | Ordinary users |
P07-16 | Torque reaches hysteresis loop | 0~3000 | ‰ | 200 | Effective immediately | Set anytime | Ordinary users |
P07-17 | Speed limit judge time | 5~300 | 0.1ms | 10 | Effective immediately | Set anytime | Ordinary users |
P07-18 | T-LMT selection | 0-AI1 1-AI2 | -- | 0 | Effective immediately | Set anytime | Manufacturer mode |
P07-19 | V-LMT selection | 0-AI1 1-AI2 | -- | one | Effective immediately | Set anytime | Manufacturer mode |