F01 — Motor 1 data

code

Code name

Setting range

value

attribute

F01.00

Motor type selection

0:asynchronous motor

1:frequency motor

0

F01.01

Rated power of motor

0.1kW ~ 1000.0kW

Mode confirm

F01.02

Rated voltage of motor

1V ~ 2000V

Mode confirm

F01.03

Motor rated current

0.01A ~ 655.35A

Mode confirm

F01.04

Rated frequency of motor

0.01Hz ~max frequency

Mode confirm

F01.05

Rated motor speed

1rpm ~ 65535rpm

Mode confirm

F01.06

Asynchronous motor stator resistance

0.001Ω ~ 65.535Ω

Tuning parameter

F01.07

Asynchronous motor rotor resistance

0.001Ω ~ 65.535Ω

Tuning parameter

F01.08

Asynchronous motor leakage reactance

0.01mH ~ 655.35Mh

Tuning parameter

F01.09

Asynchronous motor mutual inductance reactance

0.1mH ~ 6553.5mH

Tuning parameter

F01.10

Asynchronous motor no-load current

0.01A~F01-03

Tuning

parameter

F01.27

Number of encoder lines

1~65535

1024

F01.28

Encoder type

0:ABZ incremental encoder

1: UVW incremental encoder

2:Rotating Transformer

3:Sine cosine encoder

4:Line saving UVW encoder

0

F01.29

Speed feedback PG card selection

0: QEP1

1: QEP2(扩展)

0

F01.30

ABZ incremental encoder AB phase sequence

0:Forward

1:reverse

0

F01.31

Encoder installation angle

0.0~359.9°

0.0°

F01.32

UVW encoder UVW phase sequence

0:Forward

1:reverse

0

F01.33

UVW encoder bias angle

0.0~359.9°

0.0°

F01.34

Number of pole pairs for transformer

1~65535

1

F01.35

Number of UVW poles

1~65535

4

F01.36

Speed feedback PG disconnection detection time

0.0s:no operation

0.1s~10.0s

0.0s

F01.37

Motor parameter tuning

0:No operation

1:motor static tuning 1

2:Dynamic tuning

3: motor static tuning 2

0