F06 — output terminal
code | Code name | Set range | value | attribute |
|---|---|---|---|---|
F06.00 | reserve | ● | ||
F06.01 | reserve | 0: No output 1: Inverter in operation 2: Fault output 3: Frequency level detection FDT1 output 4: Frequency arrival 5: Zero speed operation (no output when stop) 6: Motor overload warning 7: Frequency converter overload warning 8: Set the count value to reach 9: Specified count value has reached 10: Length reached 11: Simple PLC program circle 12: total running time has reached 13: In frequency limit (in swing frequency limit) 14: In torque limit 15: Ready for operation 16:AI1>AI2 17: Upper limit frequency reached 18: Lower limit frequency reached (no output when stop) 19: Under voltage state 20: Communication settings 21: Reserved 22: Reserved 23: zero speed operation 2 (still output when stop) 24: total power on time has reached 25: Frequency level detection FDT2 output 26: Frequency 1 arrival 27: Frequency 2 arrival 28: Current 1 arrival 29: Current 2 arrival 30: Timed arrival 31: AI1 input exceeded limit 32: losing load 33:Reverse operation 34: no current state 35: Module temperature reached 36: Output current exceeds limit 37: Lower limit frequency reached (go on output when stopped) 38: Alarm 39: Motor over temperature 40: The running time has reached 41: Fault output | 0 | ● |
F06.02 | Relay R1 function | 2 | ● | |
F06.03 | reserve | 0 | ● | |
F06.04 | Y1 output function | 1 | ● | |
F06.05 | reserve | 0 | ● | |
F06.06 | reserve | 0: Operating frequency 1: Set frequency 2: Output current 3: Motor output torque 4: Output power 5: Output voltage 6: Pulse input 7:AI1 8:AI2 9: Reserved 10: Length 11: Record data values 12: Communication settings 13: Motor speed 14: Output current 15: Main cable voltage 16: Motor output torque 17:frequency output torque | 0 | ● |
F06.07 | AO1 output function | 0 | ● | |
F06.08 | reserve | 1 | ● | |
F06.09 | ||||
F06.10 | AO1 offset coefficient | -100.0% ~ +100.0% | 0.0% | ● |
F06.11 | AO1 gain | -10.00 ~ +10.00 | 1.00 | ● |
F06.12 | reserve | |||
F06.13 | reserve | |||
F06.14 | reserve | |||
F06.15 | AO1 output filter time | 0.00~10.00s | 0.00 | X |
F06.16 | reserve | |||
F06.17 | reserve | |||
F06.18 | reserve | |||
F06.19 | R1 output valid delay time | 0.0s ~ 3600.0s | 0.0s | ● |
F06.20 | R1 output invalid delay time | 0.0s ~ 3600.0s | 0.0s | ● |
F06.21 | reserve | |||
F06.22 | reserve | |||
F06.23 | Y1 output valid delay time | 0.0s ~ 3600.0s | 0.0s | ● |
F06.24 | Y1utput invalid delay time | 0.0s ~ 3600.0s | 0.0s | ● |
F06.25 | reserve | |||
F06.26 | reserve | |||
F06.27 | Y Output terminal effective status | 0: Positive logic 1: Anti logic One digit: Y1 Ten digit: R1 Hundred digits: reserved Thousand digits: reserved 10000 digits: reserved | 00000 | ● |
F06.28 | Y output terminal signal type | 0:current level 1:single pulse One digit:Y1 Ten digit:R1 Hundred digit:reserve Thousand digit:reserve 10000 digit:reserve | 00000 | ● |
F06.29 | Y1 output single pulse time | 0.0s ~ 3600.0s | 0.1s | ● |
F06.30 | R1 output single pulse time | 0.0s ~ 3600.0s | 0.1s | ● |