F12 — Keyboard and display

Code

Code name

Set range

value

attribute

F12.00

Digital tube missing picture inspection enable

0~1

0

X

F12.01

  1. K-key function

selection

0:M. K is invalid

1: Switching between keyboard and remote command channels

2: Forward and reverse

switching

3: Forward jog

4: Reverse Jog

3

F12.02

STOP/RESET key

0: Only valid in keyboard

operation mode

1: Effective in any mode of

operation

1

F12.03

Run display

Parameters 1

0000 ~ FFFF

Bit00: operation frequency (Hz)

Bit01: set frequency(Hz)

Bit02: main cable voltage (V)

Bit03: output voltage (V)

Bit04: output current (A)

Bit05: output power (kW)

Bit06: output torque (%)

Bit07: DI input status

Bit08: DO output status

Bit09: AI1 voltage (V)

Bit10: AI2 voltage (V)

Bit11: reserve

Bit12: count value

Bit13: length value

Bit14: Load speed display

Bit15: PID set

1F

F12.04

Run display

Parameters 2

0000 ~ FFFF

Bit00: PID feed back

Bit01: PLC stage

Bit02: PULSE input pulse

frequency(kHz)

Bit03: operation frequency 2(Hz)

Bit04: operation time left

Bit05: AI1 calibration front

voltage(V)

Bit06: AI2 calibration front

voltage(V)

Bit07: reserve

Bit08: line speed

Bit09: Current power on time (Hour)

Bit10: Current running time (Min)

Bit11: PULSE input pulse frequency (Hz)

Bit12: Communication setting value

Bit13: Encoder feedback speed (Hz)

Bit14: Main frequency X display (Hz)

Bit15: Auxiliary frequency Y display

0

F12.05

Stop display data

0000 ~ FFFF

Bit00: set frequency(Hz)

Bit01: main cable voltage (V)

Bit02: DI input status

Bit03: DO output status

Bit04: AI1 voltage (V)

Bit05: AI2 voltage (V)

Bit06: reserve

Bit07: count value

Bit08: length value

Bit09: PLC stage

Bit10: load speed

Bit11: PID set

Bit12: PULSE input pulse frequency(kHz)

Bit13: reserve

Bit14: reserve

Bit15: reserve

1

F12.06

Load speed display coefficient

0.0001 ~ 6.5000

3.0000

F12.07

Temperature of

inverter radiator

-20℃ ~ 120℃

-

X

F12.08

Keyboard second line monitoring

parameters

0~78(F13.00~F13.78)

4

F12.09

Total operation time

0h ~ 65535h

-

X

F12.10

Product name

S300A/S300b

-

X

F12.11

Software version

V1.00

-

X

F12.12

Load speed display decimal digit

One digit :F13.12 decimal point

0:0 decimal digit

1: 1 decimal digit

2: 2 decimal digit

3: 3 decimal digit

Ten digits: F13.19/F13.29

Decimal point count

1: 1 decimal digit

2: 2 decimal digit

21

F12.13

Total power on time

0 ~ 65535 hours

-

X

F12.14

Total power usage

0 ~ 65535 degrees

-

X

F12.15

Performance temporary software version number

X

F12.16

Temporary software version number for functions

X