F19 — Torque control data
功能码 | 功能码名称 | 设定范围 | 出厂值 | 属性 |
|---|---|---|---|---|
F19.00 | speed/torque control methods | 0:speed control 1:torque control | 0 | 〇 |
F19.01 | Selection of torque setting in torque control mode | 0:value setting (F19.03) 1:AI1 2:AI2 3:reserve 4:PULSE 5:communication give 6:MIN(AI1,AI2) 7:MAX(AI1,AI2) (full range of options 1-7 corresponds to the F19.03 value setting) | 0 | 〇 |
F19.02 | reserve | |||
F19.03 | torque value setting in torque control mode | -200.0% ~ 200.0% | 150.0% | ● |
F19.04 | Torque filtering | 0.00s ~ 10.00s | 0.00 | ● |
F19.05 | Torque control forward maximum frequency | 0.00Hz ~max frequency | 50.00Hz | ● |
F19.06 | Torque control reverse maximum frequency | 0.00Hz ~max frequency | 50.00Hz | ● |
F19.07 | Torque acceleration time | 0.00s ~ 650.00s | 0.00s | ● |
F19.08 | Torque deceleration time | 0.00s ~ 650.00s | 0.00s | ● |