F18 — Swinging frequency, fixed length, and counting

Code

Code name

Set range

value

attribute

F18.00

Swing frequency setting method

0:Relative to center

frequency

1:Relative to

maximum frequency

0

F18.01

Swing frequency range

0.0%~100.0%

0.0%

F18.02

Jump frequency range

0.0%~50.0%

0.0%

F18.03

Swing frequency circle

0.1s~3000.0s

10.0s

F18.04

Swing frequency

triangular wave rise time

0.1%~100.0%

50.0%

F18.05

Set length

0m ~ 65535m

1000m

F18.06

Actual length

0m ~ 65535m

0m

F18.07

Pulse count per meter

0.1 ~ 6553.5

100.0

F18.08

Set Count Values

1 ~ 65535

1000

F18.09

Specify the count value

1 ~ 65535

1000