F13 — Basic monitoring data

Code

Code name

Minimum unit

F13.00

Set frequency (Hz)

0.01Hz

F13.01

Operation frequency (Hz)

0.01Hz

F13.02

Main cable voltage (V)

0.1V

F13.03

Output voltage(V)

0.1V

F13.04

Output current(A)

0.01A

F13.05

Output current(%)

0.1%

F13.06

Output power (kW)

0.1kW

F13.07

Count value

1

F13.08

Length value

1

F13.09

AI1 voltage (V)

0.01V

F13.10

AI2 voltage(V)/ current(mA)

0.01V/0.01mA

F13.11

reserve

0.01V

F13.12

Load speed

1RPM

F13.13

DI input status

X5/X4/X3/X2/X1

F13.14

DO output status

R2/Y2/R1/Y1

F13.15

PID set

1

F13.16

PID feed back

1

F13.17

PLC stage

1

F13.18

Input pulse frequency (Hz)

0.01kHz

F13.19

Feedback speed (Hz)

0.01Hz

F13.20

Operation time left

0.1min

F13.21

AI1 calibration front voltage

0.001V

F13.22

AI2 calibration front voltage(V)/ current(mA)

0.001V/0.01mA

F13.23

Keyboard potentiometer calibration front voltage

0.001V

F13.24

Motor speed

1RPM

F13.25

Current power on time

1min

F13.26

Current operation time

0.1min

F13.27

input pulse frequency

1Hz

F13.28

Communication set value

0.01%

F13.29

Encoder feedback speed

0.01Hz

F13.30

Main frequency display

0.01Hz

F13.31

Auxiliary frequency display

0.01Hz

F13.32

View any memory address value

1

F13.33

reserve

F13.34

Motor temperature value

1℃

F13.35

Target torque (%)

0.1%

F13.36

Rotation position

1

F13.37

Power factor angle

0.1°

F13.38

ABZ position

1

F13.39

V/F Separate target voltage

1V

F13.40

V/F Separate output voltage

1V

F13.41

DI display of input status

1

F13.42

DO display of output status

1

F13.43

DI display of functional status 1 (Function 01- Function 40)

1

F13.44

DI display of functional status 2 (Function 41- Function 80)

1

F13.45

Fault information

1

F13.46

~F13.57

reserve

F13.58

Z signal counter

1

F13.59

Set frequency (%)

0.01%

F13.60

Operation frequency (%)

0.01%

F13.61

Frequency status

1

F13.62

Current fault code

1

F13.63

Point to point master communication sends torque value

0.01%

F13.64

Amount of slave station

1

F13.65

Torque upper limit

0.1%

F13.66

Communication expansion card mode

reserve

F13.67

Communication expansion card version

Display range

F13.68

reserve

F13.69

reserve

F13.70

reserve

F13.71

Communication card specific current display

Display range

F13.72

Communication card fault status

Display range

F13.73

Motor SN

0:motor 1

1:motor 2

F13.74

Motor actual output torque

-100.0%~100.0%