F07 — Multi segment instructions, simple PLC function
code | Code name | Set range | value | attribute |
|---|---|---|---|---|
F07.00 | Multi segment instruction 0 | -100.0% ~ 100.0% | 0.0% | ● |
F07.01 | Multi segment instruction 1 | -100.0% ~ 100.0% | 0.0% | ● |
F07.02 | Multi segment instruction 2 | -100.0% ~ 100.0% | 0.0% | ● |
F07.03 | Multi segment instruction 3 | -100.0% ~ 100.0% | 0.0% | ● |
F07.04 | Multi segment instruction 4 | -100.0% ~ 100.0% | 0.0% | ● |
F07.05 | Multi segment instruction 5 | -100.0% ~ 100.0% | 0.0% | ● |
F07.06 | Multi segment instruction 6 | -100.0% ~ 100.0% | 0.0% | ● |
F07.07 | Multi segment instruction 7 | -100.0% ~ 100.0% | 0.0% | ● |
F07.08 | Multi segment instruction 8 | -100.0% ~ 100.0% | 0.0% | ● |
F07.09 | Multi segment instruction 9 | -100.0% ~ 100.0% | 0.0% | ● |
F07.10 | Multi segment instruction10 | -100.0% ~ 100.0% | 0.0% | ● |
F07.11 | Multi segment instruction11 | -100.0% ~ 100.0% | 0.0% | ● |
F07.12 | Multi segment instruction12 | -100.0% ~ 100.0% | 0.0% | ● |
F07.13 | Multi segment instruction13 | -100.0% ~ 100.0% | 0.0% | ● |
F07.14 | Multi segment instruction14 | -100.0% ~ 100.0% | 0.0% | ● |
F07.15 | Multi segment instruction15 | -100.0% ~ 100.0% | 0.0% | ● |
F07.16 | simple PLC operation mode | 0: Stop at the end of a single circle 1: Maintain final value at the end of a single run 2: Always circle | 0 | ● |
F07.17 | Simple PLC power-off memory selection | One digit: Power failure memory selection 0: No memory when power failure 1: memory when power failure Ten digits: stop memory selection 0: No memory when stop 1: memory when stop | 00 | ● |
F07.18 | Simple PLC segment 0 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.19 | Simple PLC Section 0 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.20 | Simple PLC segment 1 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.21 | Simple PLC Section 1 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.22 | Simple PLC segment 2 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.23 | Simple PLC Section 2 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.24 | Simple PLC segment 3operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.25 | Simple PLC Section 3Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.26 | Simple PLC segment 4 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.27 | Simple PLC Section 4 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.28 | Simple PLC segment 5 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.29 | Simple PLC Section 5 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.30 | Simple PLC segment 6 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.31 | Simple PLC Section 6 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.32 | Simple PLC segment 7 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.33 | Simple PLC Section 7 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.34 | Simple PLC segment 8 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.35 | Simple PLC Section 8 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.36 | Simple PLC segment 9 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.37 | Simple PLC Section 9 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.38 | Simple PLC segment 10 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.39 | Simple PLC Section 10 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.40 | Simple PLC segment 11 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.41 | Simple PLC Section 11 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.42 | Simple PLC segment 12 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.43 | Simple PLC Section 12 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.44 | Simple PLC segment 13 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.45 | Simple PLC Section 13 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.46 | Simple PLC segment 14 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.47 | Simple PLC Section 14 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.48 | Simple PLC segment 15 operation time | 0.0s(h) ~ 6500.0s(h) | 0.0s(h) | ● |
F07.49 | Simple PLC Section 15 Acc/ Dec Time Selection | 0 ~ 3 | 0 | ● |
F07.50 | Simple PLC running time unit | 0:s(秒) 1:h(小时) | 0 | ● |
F07.51 | Multiple segment instruction 0 given method | 0:code F07.00 given 1:AI1 2:AI2 3:reserve 4:pulse 5:PID 6:F00.08 | 0 | ● |