F09 — Communication data

code

Code name

Set range

value

attribute

F09.00

Baud rate

0:300bps

1:600bps

2:1200bps

3:2400bps

4:4800bps

5:9600bps

6:19200bps

7:38400bps

8:57600bps

9:115200bps

5

F09.01

MODBUS

data format

0:No verification (8-N-2)

1:Even parity(8-E-1)

2:Odd parity (8-O-1)

3:No verification (8-N-1)

3

F09.02

Local address

0:Broadcast address

1 ~ 247

1

F09.03

MODBUS

response delay

0 ~ 20ms

2

F09.04

communication interrupt detection time

0.0:invalid

0.1 ~ 60.0s

0.0

F09.05

MODBUS

Data protocol

0:Non standard MODBUS

1:Standard MODBUS

1

F09.06

reading

current resolution

0:0.01A

0

F09.07

Master or slave communication

0:slave

1:master

0

F09.08

master communication sending data

0:set frequency(P13.00)

1:output frequency(P13.01)

1

F09.09

Slave receiving ratio coefficient

0.00 ~ 300.00%

100.00