F23 — AI curve setting

Code

Code name

Set range

value

attribute

F23.00

AI curve 4 minimum input

-10.00V ~ F23.02

0.00V

F23.01

AI curve 4 minimum input corresponding setting

-100.0% ~ +100.0%

0.0%

F23.02

AI curve 4 inflection point 1 input

F23.00 ~ F23.04

3.00V

F23.03

AI curve 4 inflection point 1 input corresponding setting

-100.0% ~ +100.0%

30.0%

F23.04

AI curve 4 inflection point 2 input

F23.02 ~ F23.06

6.00V

F23.05

AI curve 4 inflection point 2 input corresponding setting

-100.0% ~ +100.0%

60.0%

F23.06

AI curve 4 maximum input

F23.04 ~ +10.00V

10.00V

F23.07

AI curve 4 maximum input corresponding setting

-100.0% ~ +100.0%

100.0%

F23.08

AI curve 5 minimum input

-10.00V ~ F23.10

-10.00V

F23.09

AI curve 5 minimum input corresponding setting

-100.0% ~ +100.0%

-100.0%

F23.10

AI curve 5 inflection point 1 input

F23.08 ~ F23.12

-3.00V

F23.11

AI curve 5 inflection point 1 input corresponding setting

-100.0% ~ +100.0%

-30.0%

F23.12

AI curve 5 inflection point 2 input

F23.10 ~ F23.14

3.00V

F23.13

AI curve 5 inflection point 2 input corresponding setting

-100.0% ~ +100.0%

30.0%

F23.14

AI curve 5 maximum input

F23.12 ~ +10.00V

10.00V

F23.15

AI curve 5 maximum input corresponding setting

-100.0% ~ +100.0%

100.0%

F23.24

AI1 Setting Jump Points

-100.0% ~ 100.0%

0.0%

F23.25

AI1 Set Jump Range

0.0% ~ 100.0%

0.5%

F23.26

AI2 Setting Jump Points

-100.0% ~ 100.0%

0.0%

F23.27

AI2 Set Jump Range

0.0% ~ 100.0%

0.5%

F23.28

reserve

F23.29