F23 — AI curve setting
Code | Code name | Set range | value | attribute |
|---|---|---|---|---|
F23.00 | AI curve 4 minimum input | -10.00V ~ F23.02 | 0.00V | ● |
F23.01 | AI curve 4 minimum input corresponding setting | -100.0% ~ +100.0% | 0.0% | ● |
F23.02 | AI curve 4 inflection point 1 input | F23.00 ~ F23.04 | 3.00V | ● |
F23.03 | AI curve 4 inflection point 1 input corresponding setting | -100.0% ~ +100.0% | 30.0% | ● |
F23.04 | AI curve 4 inflection point 2 input | F23.02 ~ F23.06 | 6.00V | ● |
F23.05 | AI curve 4 inflection point 2 input corresponding setting | -100.0% ~ +100.0% | 60.0% | ● |
F23.06 | AI curve 4 maximum input | F23.04 ~ +10.00V | 10.00V | ● |
F23.07 | AI curve 4 maximum input corresponding setting | -100.0% ~ +100.0% | 100.0% | ● |
F23.08 | AI curve 5 minimum input | -10.00V ~ F23.10 | -10.00V | ● |
F23.09 | AI curve 5 minimum input corresponding setting | -100.0% ~ +100.0% | -100.0% | ● |
F23.10 | AI curve 5 inflection point 1 input | F23.08 ~ F23.12 | -3.00V | ● |
F23.11 | AI curve 5 inflection point 1 input corresponding setting | -100.0% ~ +100.0% | -30.0% | ● |
F23.12 | AI curve 5 inflection point 2 input | F23.10 ~ F23.14 | 3.00V | ● |
F23.13 | AI curve 5 inflection point 2 input corresponding setting | -100.0% ~ +100.0% | 30.0% | ● |
F23.14 | AI curve 5 maximum input | F23.12 ~ +10.00V | 10.00V | ● |
F23.15 | AI curve 5 maximum input corresponding setting | -100.0% ~ +100.0% | 100.0% | ● |
F23.24 | AI1 Setting Jump Points | -100.0% ~ 100.0% | 0.0% | ● |
F23.25 | AI1 Set Jump Range | 0.0% ~ 100.0% | 0.5% | ● |
F23.26 | AI2 Setting Jump Points | -100.0% ~ 100.0% | 0.0% | ● |
F23.27 | AI2 Set Jump Range | 0.0% ~ 100.0% | 0.5% | ● |
F23.28 | reserve | |||
F23.29 | reserve |